Search results for "Objective method"
showing 10 items of 10 documents
Objective Amplitude of Accommodation Computed from Optical Quality Metrics Applied to Wavefront Outcomes
2009
Purpose: We studied the accuracy and precision of 32 objective wavefront methods for finding the amplitude of accommodation obtained in 180 eyes. Methods: Ocular accommodation was stimulated with 0.5 D steps in target vergence spanning the full range of accommodation for each subject. Subjective monocular amplitude of accommodation was measured using two clinical methods, using negative lenses and with a custom Badal optometer. Results: Both subjective methods gave similar results. Results obtained from the Badal optometer where used to test the accuracy of the objective methods. All objective methods showed lower amplitude of accommodation that the subjective ones by an amount that varied …
Fixation pattern analysis with microperimetry in nystagmus patients
2015
Objective: To assess the usefulness of microperimetry (MP) as an additional objective method for characterizing the fixation pattern in nystagmus. Design: Prospective study. Participants: Fifteen eyes of 8 subjects (age, 12–80 years) with nystagmus from the Lluís Alcanyís Foundation (University of Valencia, Spain) were included. Methods: All patients had a comprehensive ophthalmologic examination including a microperimetric examination (MAIA, CenterVue, Padova, Italy). The following microperimetric parameters were evaluated: average threshold (AT), macular integrity index (MI), fixating points within a circle of 1° (P1) and 2° of radius (P2), bivariate contour ellipse area (BCEA) considerin…
Diagnostic Capability of a New Objective Method to Assess Meibomian Gland Visibility
2021
SIGNIFICANCE The diagnosis of dry eye disease and meibomian gland dysfunction (MGD) is challenging. Measuring meibomian gland visibility may provide an additional objective method to diagnose MGD. PURPOSE This study aimed to evaluate the ability of new metrics to better diagnose MGD, based on measuring meibomian gland visibility. METHODS One hundred twelve healthy volunteers (age, 48.3 ± 27.5 years) were enrolled in this study. Ocular surface parameters were measured using the Oculus Keratograph 5M (Oculus GmbH, Wetzlar). Subjects were classified according to the presence or absence of MGD. New metrics based on the visibility of the meibomian glands were calculated and later compared betwee…
Clinical and echographical control protocol of haemarthrosis in haemophilia patients with inhibitors: evaluation of the efficacy of recombinant facto…
2008
Summary. The intention of the ‘clinical and echographical protocol of evaluation the efficacy of recombinant activated factor VII in the haemarthrosis’ (EFFISEVEN protocol) was to provide an extensive study of the evolution of haemarthrosis, and second, of its repercussions on the degenerative process of joints. The clinical evaluation of haemarthroses and their evolution is based on a well-established methodology, although very few studies have sought to determine the correlation between pain, mobility and the objective data regarding the haemorrhage. We believe that it is necessary to unify criteria and that the EFFISEVEN protocol may contribute data that improve standards which, in turn…
Indoor Environmental Quality Survey: A Brief Comparison between Different Post Occupancy Evaluation Methods
2013
Building occupants are important factor in giving information on indoor conditions such as comfort, productivity, building performance and occupants ́ health. Even that, being their appraisal mainly based on subjective judgments, it is difficult to set up a standard and objective method for this purpose. The present work aimed to describe, analyze and compare the most common tests on this topic, in order to highlight critical, failings and strengths.
Use of ATP bioluminescence for assessing the cleanliness of hospital surfaces: A review of the published literature (1990–2012)
2014
Summary: Hospital cleanliness tends to be considered by patients and the public as an important indicator of the general quality of healthcare. Tests for detecting the presence of adenosine triphosphate (ATP) as a proxy of microbial contamination are increasing in popularity, and several studies have been conducted on this topic in the last few decades. The aim of the present study was to review the published literature on this topic and summarize and discuss the available results. The review focused on relevant English-language articles that were identified through searches of two databases [PubMed and Scopus (1990–2012)] by using the keywords “ATP”, “bioluminescence”, “hospital”, and “sur…
Contact lenses: do they really change the opticalperformance?
1996
Abstract In this investigation the quality of two types of optical correction, hydrogel contact lenses and ophthalmic lenses, wascompared by measuring the modulation transferfunction (MTF) of the correcting lens plus visual optics system using an objective method. A merit function was defined in order to allow the direct comparison between the optical performance with the two corrections. A study on 10 subjects was undertaken, measuring the MTF of both corrections by using the double pass method. The results show that the optical quality of contact lenses was higher than that with ophthalmic lenses. The contrast sensitivity function (CSF) and visual acuity (VA) were determined as subjective…
Orthodontic Treatment and Healthcare Goals: Evaluation of Multibrackets Treatment Results Using PAR Index (Peer Assessment Rating)
2020
Background: The evaluation of orthodontic treatment outcomes using an objective method is important in order to maintain high treatment quality and final healthcare of patients. It allows professionals and university students to raise the level of the therapy. The aim of this study was to assess the orthodontic treatment outcomes in an Italian postgraduate School of Orthodontics using Peer Assessment Rating (PAR) Index. Methods: A sample of 50 patients treated in a postgraduate program was randomly selected. PAR index was used to assess pre-treatment and post-treatment study casts by two different examiners. The influence of different variables such as gender, treatment method, and need for…
Influence of the tear film on optical quality of the eye
1997
The optical quality of the tear film of the eye was tested by measuring the retinal image before and after the break-up time (BUT). An objective method was used based on the evaluation of the retinal image of a point test projected onto the fovea. The loss of an entire tear film would result in a decrease in the optical quality because of corneal irregularities and the formation of an irregular tear lens after the BUT. Our results confirm the expected loss both of non-contact lens wearers and contact lens wearers. Also, the fact that the optical deterioration found after the BUT is greater for contact lens wearers confirms that soft contact lens wear produces a disruption of the tears.
Directly measured and self-reported physical activity in a sample of Finnish secondary school students
2012
Previous studies based on self-reports show that a majority of children and adolescents in Western countries fail to achieve the recommendation of 60 minutes moderate to vigorous physical activity (PA) on a daily basis. The specific aim of the study was to analyze the relationship between directly measured and self-reported PA in a cross-sectional sample of Finnish secondary school students. Moreover, how large proportion of adolescents accumulate at least 60 minutes of moderate to vigorous PA on a daily basis using self-reports and direct measure scores. Methods: Participants were recruited from a secondary school located in Northeast Finland. The sample comprised 96 students (58 girls, 38…